- Piece/Pieces
- 1
- Number
- 4200 INR
- IP67
- Hertz (HZ)
- Volt (V)
- Energy
- Millimeter (mm)
- Grams (g)
Features
ÃÂ÷        Soft Startup : In order to avoid sudden shock to the feed material and vibratory feeder, the controller can gently increase output voltage from 0 to the preset value when startup.
ÃÂ÷        Preset Speeds : 4 preset feed speeds can be stored and output by external short-circuit signal.
ÃÂ÷        Remote ON/OFF ControlÃÂâ : The controller has 2 groups of ON/OFF control pins. Switch sensor or PLC can be connected to them to turn on/off the controller.
ÃÂ÷        Photoelectric ON/OFF Control : The CUH Intelligent Photoelectric Sensor can be connected to turn on/off the controller.
ÃÂ÷        Remote Speed Control : Output Voltage of the controller can be adjusted remotely by an external potentiometer, a PLC, or a 1-5V DC signal.
ÃÂ÷        DC Control Output : The controller can output low voltage DC power associated with logical relation setting of the ON/OFF Control to drive a solenoid, an electrical relay or other external devices.
ÃÂ÷        Overheat Protection : If internal temperature of the controller gets too high, the controller will stop its output to protect itself.
ÃÂ÷        Overcurrent Protection : If output current exceeds its rated value by mis-operation, the controller will stop its output to protect the
ÃÂ÷        controller and vibratory feeder.
ÃÂ÷        Short-Circuit Protection : If output of the controller is short-circuited, the fuse inside the controller will be blown to protect the controller and vibratory feeder from further damage.
ÃÂ÷        Technical Specifications
ITEM | Range | Unit | Description | |
Min | Max | |||
Input voltage | 85 | 260 | V | AC RMS Value |
Output voltage | 0 | 260 | V | Less than Input voltage |
Output Current | 0 | 6 | A | |
Output Frequency | 50/100 | Hz | Mains Frequency is 50Hz | |
60/120 | Hz | Mains Frequency is 60Hz | ||
OutPut Power | 0 | 1320 | VA | |
Output Waveform | Tangent Sine | |||
Viltage Adjestment Accuracy | 1 | v | ||
ON/OFF delay | 0 | 20 | s | |
ON/OFF Delay Accuracy | 0.1 | s | ||
Soft Startup Time | 0 | 10 | s | |
DC Control output Voltage | 22 | 26 | V | DC output associated with ON/OFF control |
DC Control output current | 0 | 200 | mA | |
Stand by Power Consumption | 1.5 | 3 | w | |
Display Method | 5 | Digit | LED Digital Tube | |
Control Method | 1-5 | V | Remote Speed Control Voltage | |
Standard TTL Electric Level | Switching Signal | |||
/ | 6 Buttons + LED screen | |||
Work Space | -10 | 60 | ÃÂðC | Non-Condensing |
Work Space Humidity | 10 | 85 | %v |
 Â
- Cash in Advance (CID) Cheque
- Week
- Contact us for information regarding our sample policy
- 3 % extra
- All India
- Authorised Distributor of CUH